Trykluft Standard ISO 8573-2010

We use ISO 8573-2010 as a reference when choosing compressed air filters, and to find out to which level it is necessary to clean the air. ISO 8563-2010 contains particles class, water class and oil class. When refering to an ISO class, the classes are written in that order. As an example: ISO class 2.4.1

Class Particles pr. m³ Dew Point Residual Oil Content
0,1 - 0,5 µm 0,5 - 1 µm 1 - 5 µm
1

≤ 20.000

≤ 400

≤ 10

-70°C ≤ 0,01 mg/m³
2

≤ 400.000

≤ 6.000

≤ 100

-40°C ≤ 0,1 mg/m³
3

≤ 90.000

≤ 1.000

-20°C ≤ 1 mg/m³
4

≤ 10.000

+3°C ≤ 5 mg/m³
5

≤ 100.000

+7°C
6 +10°C

Application Particle Class Dew Point Class Oil Class
General automatic 2-5 3-4 2
Blown air 5 5 2
Laser cutting 1 1-2 1
Paints 1 2-3 1-2
Surface 1-3 3-4 1
Sandblasting 3-5 3-5 4
Breathing Air 1 3 1
Process Industry
Automatic (cylinders, solenoid valves) 1-5 3-4 1-3
General compressed air 3-5 4-5 2
Measurement & control engineering 1 2-4 1
Process air 1-3 2-3 1
Blasting / powder transport 1-3 2-4 1
Food Industry
Automatic (cylinders, solenoid valves) 1-3 3-4 1-2
Wrappers 1-3 3-4 1-2
Tapping columns 1-3 3-4 1-2
Air tools in the production room 1-3 3-4 1-2
Air tools in workshop 4-5 4-5 4